NRCDose Release Notes

Code & Graphical User Interface (GUI) Change:
Code & Graphical User Interface (GUI) Change:
  • Updated the NRCDose3 installer routine with version 1.1.0, where the installer did not always install the most up-to-date versions of the file.
Code & Graphical User Interface (GUI) Change:
  • LADTAP - For the individual ALARA calculations, user input for dilutions were switched between drinking water and “all other” pathways. The drinking water dilution was being assigned to the calculations for all other pathways and the all other pathways dilution was being assigned to the drinking water pathway. Interface change to correctly apply the dilution factors.
Code & Graphical User Interface (GUI) Change:
  • Support for updated Dose Conversion Factors (DCF) values - Previous versions of NRCDose (LADTAP II, GASPAR II and XOQDOQ) only utilized one set of DCF values, largely those contained in RG 1.109 and based on ICRP-2 methodology. NRCDose3 allows the user to select either the ICRP-2 (Default) DCF values, or those from ICRP-30 or ICRP-72.